Switch S3 Acceleration/deceleration
-1 -2 -3 -4 ramp time
0 1 0 1 8.0 sec
4.2 Selection of the motor type
The motor type is selected by switches S4-2, S4-3 and S4-4. There are several motor dependant parameters which
are set according to the selected motor (i.e. the operator selects a parameter set). The MF06-motors are selected
as follows:
S4
Motor type Nominal frequency Nominal power
-2 -3 -4
0 0 0 MF06MA200 100Hz (120Hz) 0.3kW (0.37kW)
1 0 0 MF06MA100 80Hz 0.65kW
0 1 0 MF06LA200 100Hz (120Hz) 0.45kW (0.55kW)
1 1 0 MF06LA100 80Hz 0.65kW
0 0 1 2*MF06MA200 100Hz (120Hz) 2*0.3kW (2*0.37kW)
1 0 1 MF06L-200 35 Hz 0.15kW